Homepage | what does that do? | Common Faults | Questions Answered | Manufacturers |

Component Test Program

Creda

WMA30PE, WMA31PE, WMA32PE & WMA33PE

Before you start the test program make sure that the door is closed and the machine is switched ON

 

  1. Start with the selector at 'Off' or 'O'
  2. Turn the selector to 'F' while pressing the 'Super Rinse' and 'Rinse Hold' buttons. Continue holding the buttons for a count of 5.
  3. The 'Super Rinse','Rinse Hold','Pre-wash' &' Wash' LEDs will now start flashing.
  4. Press 'Start/Cancel' for a count of 2. The 'Super Rinse' and 'Rinse Hold' LEDs will continue to flash
  5. Choose a component you need to test and select the appropriate program from 'A' to 'H'
  6. Touch the 'Start/Cancel' button and the option 'Super Rinse ' & 'Rinse Hold' LEDs will stop flashing and light permanently to say the test has started.
  7. The chosen component will now cycle on and off at one second intervals. The interlock when tested will energies and de-energies as quickly as possible.
  8. Touch the 'Start/Cancel' button again and the test will stop, the option 'Super Rinse' and 'Rinse Hold' LEDs will again start flashing. Repeat the procedure to test the other components
  9. To end the program just turn the selector to the 'off' position 'O'

         

Program letter
Component to be tested
A
Not used
B
Pre-Wash and Rinse Solenoid Valve
C
Main wash Cold Solenoid Valve
D
Drain Pump
E
Heater Relay
F
Door Interlock
G
Drum Movement (55rpm)
H
All the above Components

 

 

NOTE;

If the drum does not have sufficient water (more than 6 liters) the heater will not come on because the pressure switch will isolate the neutral supply