Component Test Program

Hotpoint

WMA5P-WMA9,10,11,12,13,15,20,22--WMT01,02,03,05--SCR11

Before you start the test program make sure that the door is closed and the machine is switched ON

 

  1. Start with the selector at 'Off'
  2. Turn the selector to 'F' while pressing option buttons '1' & '2'. Continue holding the buttons for a count of 5.
  3. The option '1' & '2' LEDs will now start flashing.
  4. Press 'Start' for a count of 2. The LEDs will continue to flash
  5. Choose a component you need to test and select the appropriate program from 'A' to 'H'
  6. Touch the 'Start' button and the option '1' & '2' LEDs will stop flashing and light permanently to say the test has started.
  7. The chosen component will now cycle on and off at 1 second intervals. The interlock when tested will energies and de-energies as quickly as possible.
  8. Touch the 'Start' button again and the test will stop, the option '1' and '2' LEDs will again start flashing. Repeat the procedure to test the other components
  9. To end the program just turn the selector to the 'off' position

         

Program letter
Component to be tested
A
Hot Water Solenoid Valve
B
Pre-Wash and Rinse Solenoid Valve
C
Main wash Cold Solenoid Valve
D
Drain Pump
E
Heater Relay
F
Door Interlock
G
Drum Movement (55rpm)
H
All the above Components

 

 

NOTE;

If the drum does not have sufficient water (more than 6 liters) the heater will not come on because the pressure switch will isolate the neutral supply